Chiller and ventilation systems play a critical role in the infrastructure of data centers and other critical environments. These systems are essential to maintaining optimal temperature, humidity, and air quality levels, ensuring reliable performance of critical equipment and minimizing downtime. For example, data centers require constant cooling to maintain the high-density enclosed spaces, which generate a significant amount of heat. Without proper cooling, the sensitive electronic components are at risk of overheating, leading to equipment failure and costly downtime.
What is Chiller and Ventilation System?
Chiller systems are refrigeration systems that lower the temperature of machinery, industrial spaces, and process fluids by removing heat from the system and transferring it elsewhere. When integrated with heat-sensitive processes, chillers prevent thermal damage to process equipment, ensuring no alterations to the final products from exposure to unsuitable temperatures. The data center chiller systems provide precision cooling capabilities that are necessary to maintain consistent temperature and humidity levels, the data center chiller design is to ensure the reliable performance of critical equipment. Our company offers a range of chiller options, including air-cooled and water-cooled systems, variable speed drives, and energy-efficient chillers.
Ventilation systems, on the other hand, are mechanical structures of connected devices that control airflow within confined spaces, introducing a constant supply of fresh air while channeling stale air back out. For data center ventilation & server room ventilation, our ventilation systems help to maintain a clean and healthy environment by filtering out contaminants and ensuring that the air is free of dust, debris, and other harmful particles. This helps to prevent equipment failure and downtime caused by clogged air filters and other air quality issues. Our company offers a range of ventilation system options, including server room HEPA filters, data center HEPA filter, clean room environmental AC systems, fan coil units, pretreated air units, and cold aisle containment.
How can we help?
At Newtech, we specialize in providing turnkey solutions for data centers, server rooms, computer rooms and critical environments. We also understand the pain points of chiller and ventilation systems for critical facilities. With a service scope of assessment, consultancy, equipment sourcing and procurement, installation, testing, and facility maintenance, our specialized team of experts will work closely with you to conduct data center chiller design, data center ventilation design and implement a chiller and ventilation system that meets your unique needs, ensuring optimal performance and reliability. We will also leverage our extensive experience in designing and implementing chiller and ventilation systems (such as data center chiller control system) that meet the unique needs of clients’ critical environments, e.g. data center, server room, computer room.
Our service scope includes air-conditioning and mechanical ventilation systems for server room ventilation & data center ventilation, such as data center chiller design, central chiller plants, computer room air chillers, computer room air conditioning units (CRACs), adaptive cooling solutions, and clean room environmental AC systems. We also offer cold aisle containment solutions, server room HEPA filters and data center HEPA filters to ensure optimal air quality and airflow. Our team of skilled technicians is available to provide regular maintenance, repairs, and upgrades, minimizing downtime and ensuring reliable and efficient operation.
In the consultancy phase before projects, we work closely with our clients to understand their specific requirements, taking into account factors such as the size of the facility, the type of equipment being used, and the desired level of precision cooling and air quality.
As for procurement and project implementation, we offer a wide range of chiller and ventilation system options, including air-cooled and water-cooled systems, variable speed drives, and energy-efficient chillers. Our ventilation systems are designed to ensure optimal air quality and airflow, using the latest technology to filter out contaminants and maintain a clean and healthy environment.
In addition to design and implementation, we also provide ongoing maintenance and support services to ensure that your chiller and ventilation systems (such as your data center chiller, server chiller, computer room air chillers) are operating at peak performance. Our team of skilled technicians is available to provide regular maintenance, repairs, and upgrades, minimizing downtime and ensuring reliable and efficient operation.
Whether you are looking to data center chiller design, data center chiller control system or upgrade an existing critical environment, we are here to help. Contact us today to learn more about how our chiller and ventilation systems can help optimize your critical infrastructure and ensure reliable performance.
Key components of chiller & ventilation system
Central Chiller Plant
A central chiller plant is a centralized cooling system that provides chilled water to multiple cooling units in a data center. It typically consists of a chiller, pumps, cooling towers, and piping.
Advantages of Central Chiller Plant:
- Efficient use of space
- Consistent temperature control
- Reduced energy consumption
- Lower maintenance costs
Computer Room Air Conditioning Unit (CRAC)
A computer room air conditioning unit is a type of precision cooling system that is designed specifically for data centers. It provides precise temperature and humidity control to protect critical equipment.
Advantages of CRAC:
- Precision temperature and humidity control
- Reduced energy consumption
- Improved equipment reliability
- Easy maintenance and serviceability
Fan Coil Unit / Pretreated Air Unit
A fan coil unit is a type of air conditioning system that uses a fan and a coil to control the temperature of a room. A pretreated air unit is a similar system that includes a pre-treatment system to filter and clean the air.
Advantages of Fan Coil Unit / Pretreated Air Unit:
- Flexible installation options
- Energy-efficient operation
- Improved air quality
- Reduced noise levels
Adaptive Cooling Solution
Adaptive cooling solutions are designed to dynamically adjust cooling capacity based on the changing needs of a data center. This helps to ensure optimal temperature and humidity levels while minimizing energy consumption.
Advantages of Adaptive Cooling Solution:
- Energy-efficient operation
- Reduced maintenance requirements
- Improved equipment reliability
- Scalable and flexible design
Clean Room Environmental AC System
Clean room environmental AC systems are designed to maintain a clean and sterile environment in critical facilities such as data centers, pharmaceutical labs, and hospitals. They use HEPA filters and other advanced technologies to filter out contaminants and maintain a clean environment.
Advantages of Clean Room Environmental AC System:
- Improved air quality
- Reduced equipment downtime
- Increased equipment reliability
- Lower maintenance costs
Cold Aisle Containment
Cold aisle containment is a design technique used in data centers to improve cooling efficiency and reduce energy consumption. It involves enclosing the cold aisle with walls or curtains to prevent cold air from escaping.
Advantages of Cold Aisle Containment:
- Uniform temperature across cabinet height
- Improved ventilation
- Lower operating costs
- Increased equipment reliability
HEPA Filter
HEPA filters are high-efficiency air filters that are designed to remove 99.97% of all airborne particles down to 0.3 microns in size. They are commonly used in critical environments such as data centers (data center HEPA filters), server rooms (server room HEPA filters), clean rooms, and hospitals.
Advantages of HEPA Filter:
- Improved air quality
- Reduced equipment downtime
- Increased equipment reliability
- Lower maintenance costs